[dhoak@demi 20JUL20VG]$ vgosDbProcLogs -zc -s GGAO12M -s KOKEE12M -s MACGO12M -s RAEGYEB -s WETTZ13S -k pcmt 20JUL20VG_V003_iMIT_kall.wrp 
The station GGAO12M is added to the process list.
The station KOKEE12M is added to the process list.
The station MACGO12M is added to the process list.
The station RAEGYEB is added to the process list.
The station WETTZ13S is added to the process list.
The kind pcmt is added to the types of files to process.
14:40:22 vgosDbProcLogs-0.5.0 (Balmoral): starting
14:40:22 vgosDbProcLogs-0.5.0 (Balmoral): the vgosDb object has been created
14:40:26 Warning: SgVlbiSession::getDataFromVgosDb(): no data for S-band have been found: 20JUL20VG
14:40:26 SgVgosDb::loadObsEffFreqs(): the vgosDb variable EffFreq for the band [X] is empty
14:40:26 SgVgosDb::loadMiscFourFit(): the vgosDb variable MiscFourFit for the band [X] is empty
14:40:26 SgVlbiSession::getDataFromVgosDb(): reading Fourfit Info for the X-band has failed
14:40:26 SgVgosDb::loadObsNumGroupAmbigs(): the vgosDb variable NumGroupAmbig for the band [X] is empty
14:40:26 SgVgosDb::loadObsCalIonGroup(): the vgosDb variable Cal_SlantPathIonoGroup for the band [X] is empty
14:40:27 SgVgosDb::loadObsEditData(): the vgosDb variable Edit is empty
14:40:28 SgVgosDb::loadStationRefClockOffset(): the vgosDb variable RefClockOffset for the station GGAO12M  is empty
14:40:28 SgVgosDb::loadStdObsCalibration(): the vgosDb variable Cal-Cable is empty
14:40:28 SgVgosDb::loadStationRefClockOffset(): the vgosDb variable RefClockOffset for the station KOKEE12M is empty
14:40:28 SgVgosDb::loadStdObsCalibration(): the vgosDb variable Cal-Cable is empty
14:40:28 SgVgosDb::loadStationRefClockOffset(): the vgosDb variable RefClockOffset for the station MACGO12M is empty
14:40:28 SgVgosDb::loadStdObsCalibration(): the vgosDb variable Cal-Cable is empty
14:40:28 SgVgosDb::loadStationRefClockOffset(): the vgosDb variable RefClockOffset for the station ONSA13NE is empty
14:40:28 SgVgosDb::loadStationRefClockOffset(): the vgosDb variable RefClockOffset for the station ONSA13SW is empty
14:40:28 SgVgosDb::loadStationRefClockOffset(): the vgosDb variable RefClockOffset for the station RAEGYEB  is empty
14:40:28 SgVgosDb::loadStationRefClockOffset(): the vgosDb variable RefClockOffset for the station WESTFORD is empty
14:40:28 SgVgosDb::loadStationRefClockOffset(): the vgosDb variable RefClockOffset for the station WETTZ13S is empty
14:40:28 SgVgosDb::loadEccentricities(): the vgosDb variable Eccentricity is empty
14:40:28 SgVgosDb::loadAtmSetup(): the vgosDb variable AtmSetup is empty
14:40:28 SgVgosDb::loadClockSetup(): the vgosDb variable ClockSetup is empty
14:40:28 SgVgosDb::loadCalibrations(): the vgosDb variable CalibrationSetup is empty
14:40:28 SgVgosDb::loadSelectionStatus(): the vgosDb variable SelectionStatus is empty
14:40:28 SgVgosDb::loadSolveWeights(): the vgosDb variable GroupBLWeights is empty
14:40:28 SgVgosDb::loadClockBreaks(): the vgosDb variable ClockBreak is empty, no clock breaks yet
14:40:28 SgVgosDb::checkFormat(): cannot find the variable "TAI- UTC" in the file ./Session/LeapSecond.nc
14:40:28 Warning: SgVlbiSession::getDataFromVgosDb(): no Reference Clock attribute has been found for the session
14:40:28 SgVlbiSession::selfCheck(): the X-band is set as the primary one
14:40:28 SgVlbiSession::selfCheck(): the record mode has been set to "NChan:32 Rbw:2048.0 Bps:2"
14:40:28 SgVlbiSession::checkChannelSetup(): the session is ok
14:40:28 SgVlbiSession::selfCheck(): the session selfcheck has been completed
14:40:28 vgosDbProcLogs-0.5.0 (Balmoral): Library ID: SgLib-0.7.0 (Oakdale) released on 03 Mar, 2020
14:40:28 vgosDbProcLogs-0.5.0 (Balmoral): Driver  ID: vgosDbProcLogs-0.5.0 (Balmoral) released on 03 Mar, 2020
14:40:28 vgosDbProcLogs-0.5.0 (Balmoral): Host    ID: demi (Hw: x86_64; Sw: 3.10.0-693.21.1.el7.x86_64 version of Linux)
14:40:28 vgosDbProcLogs-0.5.0 (Balmoral): User    ID: Daniel Hoak <dhoak@mit.edu>, MIT Haystack
14:40:28 vgosDbProcLogs-0.5.0 (Balmoral): User command: "vgosDbProcLogs -zc -s GGAO12M -s KOKEE12M -s MACGO12M -s RAEGYEB -s WETTZ13S -k pcmt 20JUL20VG_V003_iMIT_kall.wrp"
14:40:28 vgosDbProcLogs-0.5.0 (Balmoral): Input data  : ./20JUL20VG_V003_iMIT_kall.wrp
14:40:28 vgosDbProcLogs-0.5.0 (Balmoral): the session VO0202 (20JUL20VG) has been imported from vgosDb data set
14:40:28 vgosDbProcLogs-0.5.0 (Balmoral): the cable cal were reset for selected station(s) GGAO12M, KOKEE12M, MACGO12M, RAEGYEB, WETTZ13S of the session VO0202 (20JUL20VG)
14:40:28 Warning: SgNetworkStations::readFile(): got a duplicate record " Ca CAMBRIDG --------- ---- Cambridge, UK (VLBA)" for the station name "CAMBRIDG" in the ns-codes file [/500/oper/master/ns-codes.txt]
14:40:28 Warning: SgNetworkStations::readFile(): got a duplicate record " Cb CAMBRIDG --------- ---- Cambridge, UK (Ryle)" for the station name "CAMBRIDG" in the ns-codes file [/500/oper/master/ns-codes.txt]
14:40:28 Warning: SgNetworkStations::readFile(): got a duplicate record " Ef EFLSBERG 14209S001 7203 Effelsberg, Germany (originally Mk4, now common EVN usage)" for the station name "EFLSBERG" in the ns-codes file [/500/oper/master/ns-codes.txt]
14:40:28 Warning: SgNetworkStations::readFile(): got a duplicate record " Jv JODRELL2 --------- ---- VLBA, Jodrell Bank, UK" for the station name "JODRELL2" in the ns-codes file [/500/oper/master/ns-codes.txt]
14:40:28 SgVlbiSession::importDataFromLogFiles(): checking [/500/sessions/2020/vo0202/] directory for station log files
14:40:28 SgVlbiSession::importDataFromLogFiles(): processing /500/sessions/2020/vo0202/vo0202gs.pcmt.BCD.XY.dat, a PCMT file for GGAO12M station
14:40:28 SgStnLogCollector::readLogFile(): station GGAO12M: 939 strings of the log file (68K) were read
14:40:28 SgStnLogReadings::verifyReadings(): station GGAO12M: insufficient number (0) of meteo parameters; skipped
14:40:28 SgStnLogReadings::verifyReadings(): station GGAO12M: cannot find any usable cablelong measurements
14:40:28 Warning: SgStnLogReadings::verifyReadings(): station GGAO12M: cannot determine the cable calibration sign
14:40:28 Warning: SgStnLogReadings::verifyReadings(): no default cable cal list were provided
14:40:28 SgStnLogReadings::propagateData(): station GGAO12M: 753 exact matches of cable calibrations were found
14:40:28 SgVlbiSession::importDataFromLogFiles(): processing /500/sessions/2020/vo0202/vo0202k2.pcmt.BCD.XY.dat, a PCMT file for KOKEE12M station
14:40:28 SgStnLogCollector::readLogFile(): station KOKEE12M: 720 strings of the log file (52K) were read
14:40:28 SgStnLogReadings::verifyReadings(): station KOKEE12M: insufficient number (0) of meteo parameters; skipped
14:40:28 SgStnLogReadings::verifyReadings(): station KOKEE12M: cannot find any usable cablelong measurements
14:40:28 Warning: SgStnLogReadings::verifyReadings(): station KOKEE12M: cannot determine the cable calibration sign
14:40:28 Warning: SgStnLogReadings::verifyReadings(): no default cable cal list were provided
14:40:28 SgStnLogReadings::propagateData(): station KOKEE12M: 532 exact matches of cable calibrations were found
14:40:28 SgVlbiSession::importDataFromLogFiles(): processing /500/sessions/2020/vo0202/vo0202mg.pcmt.BCD.XY.dat, a PCMT file for MACGO12M station
14:40:28 SgStnLogCollector::readLogFile(): station MACGO12M: 952 strings of the log file (68K) were read
14:40:28 SgStnLogReadings::verifyReadings(): station MACGO12M: insufficient number (0) of meteo parameters; skipped
14:40:28 SgStnLogReadings::verifyReadings(): station MACGO12M: cannot find any usable cablelong measurements
14:40:28 Warning: SgStnLogReadings::verifyReadings(): station MACGO12M: cannot determine the cable calibration sign
14:40:28 Warning: SgStnLogReadings::verifyReadings(): no default cable cal list were provided
14:40:28 SgStnLogReadings::propagateData(): station MACGO12M: 749 exact matches of cable calibrations were found
14:40:28 SgVlbiSession::importDataFromLogFiles(): processing /500/sessions/2020/vo0202/vo0202yj.pcmt.BCD.XY.dat, a PCMT file for RAEGYEB station
14:40:28 SgStnLogCollector::readLogFile(): station RAEGYEB: 759 strings of the log file (55K) were read
14:40:28 SgStnLogReadings::verifyReadings(): station RAEGYEB: insufficient number (0) of meteo parameters; skipped
14:40:28 SgStnLogReadings::verifyReadings(): station RAEGYEB: cannot find any usable cablelong measurements
14:40:28 Warning: SgStnLogReadings::verifyReadings(): station RAEGYEB: cannot determine the cable calibration sign
14:40:28 Warning: SgStnLogReadings::verifyReadings(): no default cable cal list were provided
14:40:28 SgStnLogReadings::propagateData(): station RAEGYEB: 577 exact matches of cable calibrations were found
14:40:28 SgVlbiSession::importDataFromLogFiles(): processing /500/sessions/2020/vo0202/vo0202ws.pcmt.ABC.XY.dat, a PCMT file for WETTZ13S station
14:40:28 SgStnLogCollector::readLogFile(): station WETTZ13S: 791 strings of the log file (56K) were read
14:40:28 SgStnLogReadings::verifyReadings(): station WETTZ13S: insufficient number (0) of meteo parameters; skipped
14:40:28 SgStnLogReadings::verifyReadings(): station WETTZ13S: cannot find any usable cablelong measurements
14:40:28 Warning: SgStnLogReadings::verifyReadings(): station WETTZ13S: cannot determine the cable calibration sign
14:40:28 Warning: SgStnLogReadings::verifyReadings(): no default cable cal list were provided
14:40:28 SgStnLogReadings::propagateData(): station WETTZ13S: 589 exact matches of cable calibrations were found
14:40:28 vgosDbProcLogs-0.5.0 (Balmoral): import of data from station log files has been complete
14:40:29 SgVgosDb::createWrapperFileName(): the organization name has been adjusted: MIT => MHO
14:40:29 SgVlbiSession::putDataIntoVgosDb(): the session 20JUL20VG has been updated, elapsed time: 1227.00 ms
14:40:29 vgosDbProcLogs-0.5.0 (Balmoral): export of data into vgosDb set has been complete
14:40:29 vgosDbProcLogs-0.5.0 (Balmoral): the elapsed time to process 14983 observations is: 07.72sec (7.72 sec)