IVS Analysis Report for V24002 (20240102-v24002) This report is the official IVS analysis report that corresponds to the database maintained by the IVS Data Centers for this session. (Analyzed by NVI Oper, NASA Goddard Space Flight Center VLBI Analysis Center. Spoolfile source: nuSolve solutions.) Problems: WETTZ13S(Ws) Maser Repair. KOKEE12M(K2) No clock found in logs. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 0 Number of observations rejected during analysis: 1 observation 30, KOKEE12M:WETTZ13S, 1030+415, 17:59:33, which fits at 83.6 +/- 22.3 ps Other comments: None. Parameterization: 6 parameters: UT1 offset atmosphere offset for: KOKEE12M WETTZ13S clock offset, first order term, and second order term for: WETTZ13S Clock breaks: None Session statistics Observations: 57 scheduled 57 correlated (included in the database) 57 recoverable (usable in Solve/nuSolve) 56 used Session fit: 20.595 ps UT1 formal error: 2.49 microsec Source Performance Number of Observations Scheduled Correlated* Used 0716+714 6 6 6 0827+243 4 4 4 1015+359 1 1 1 1030+415 2 2 1 1053+704 6 6 6 NRAO512 2 2 2 1732+389 5 5 5 1746+470 5 5 5 1751+288 2 2 2 1758+388 1 1 1 1803+784 5 5 5 1806+456 4 4 4 1846+322 6 6 6 2000+472 5 5 5 2229+695 3 3 3 ------------ --------- ---------- ------ Source Total 57 57 56 * Correlated means included in database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.