BKG Analysis Report for II4032 (20240201-ii4032) This report is a contributed analysis report that does not correspond to the database maintained by the IVS Data Centers for this session. (Analyzed by Gerald Engelhardt, Federal Agency for Cartography and Geodesy (BKG), Spoolfile source: interactive nuSolve analysis.) Problems: None. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 3 observation 10, 1732+389, KOKEE :WETTZELL, 23:45:00, quality codes - S:9, X:0 observation 25, 1732+389, KOKEE :WETTZELL, 00:07:58, quality codes - S:9, X:0 observation 35, 1732+389, KOKEE :WETTZELL, 00:24:21, quality codes - S:9, X:0 Number of observations rejected during analysis: 4 observation 5, KOKEE :WETTZELL, 1732+389, 23:37:02, which fits at -349.2 +/- 72.6 ps observation 20, KOKEE :WETTZELL, 1732+389, 00:00:15, which fits at -173.6 +/- 104.0 ps observation 27, KOKEE :WETTZELL, 3C418, 00:10:58, which fits at 159.4 +/- 74.0 ps observation 30, KOKEE :WETTZELL, 1732+389, 00:16:07, which fits at -329.1 +/- 95.1 ps Other comments: Correlator TIMETAG: 2024/02/02 08:20:01. Parameterization: 6 parameters: UT1 offset atmosphere offset for: KOKEE WETTZELL clock offset (0), first order term (1), and/or second order term (2) for: WETTZELL (0,1,2) Clock breaks: None. ----------------------------------------- Session Statistics Observations: 39 scheduled (correlation report not supported) 39 correlated (included in database) 36 recoverable (usable in Solve/nuSolve) 32 used Session fit: 49.250 ps UT1 formal error: 11.260 microsec ----------------------------------------- Source Performance Number of Observations Scheduled(*) Correlated* Used 0016+731 1 1 1 0133+476 6 6 6 0202+319 7 7 7 1039+811 7 7 7 1732+389 7 7 1 1803+784 1 1 1 2229+695 2 2 2 3C371 1 1 1 3C418 7 7 6 ------------ --------- ---------- ------ Source Total 39 39 32 * Correlated means included in the database. (*) All possible observations on scheduled network. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.