NASA Analysis Report for Z23023 ($23JAN23MH) This report is a contributed analysis report that does not correspond to the database maintained by the IVS Data Centers for this session. (Analyzed by Sergei Bolotin, NVI, Inc. / NASA Goddard Space Flight Center. Spoolfile source: interactive solve/nuSolve analysis.) Problems: None. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 7 observation 7, HOBART12:HART15M , 1936-155, 06:40:02, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 12, HOBART12:HART15M , 1004-500, 06:51:42, quality code X: 9 S: 0, fringe code X: ' ' S: ' ' observation 18, HOBART12:HART15M , 1936-155, 07:00:15, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 19, HOBART12:HART15M , 3C446 , 07:01:56, quality code X: 0 S: 0, fringe code X: ' ' S: ' ' observation 20, HOBART12:HART15M , 2227-088, 07:02:54, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 21, HOBART12:HART15M , 2144+092, 07:04:41, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 24, HOBART12:HART15M , 1004-500, 07:14:23, quality code X: 0 S: 0, fringe code X: ' ' S: ' ' Number of observations rejected during analysis: 0 Other comments: This is a preliminary release using the old database name convention. Parameterization: 6 parameters: UT1 offset atmosphere offset for: HART15M HOBART12 clock offset, first order term, and second order term for: HOBART12 Clock breaks: None Session statistics Observations: 30 scheduled 30 correlated (included in the database) 23 recoverable (usable in Solve/nuSolve) 23 used Session fit: 38.001 ps UT1 formal error: 14.23 microsec Source Performance Number of Observations Scheduled Correlated* Used 0530-727 2 2 2 1004-500 2 2 0 1057-797 2 2 2 1758-651 1 1 1 1908-201 2 2 2 1921-293 3 3 3 1936-155 2 2 0 1954-388 2 2 2 1958-179 3 3 3 2008-159 3 3 3 2059+034 2 2 2 2126-158 1 1 1 2144+092 1 1 0 2208-137 1 1 1 3C446 1 1 0 2227-088 1 1 0 2329-384 1 1 1 ------------ --------- ---------- ------ Source Total 30 30 23 * Correlated means included in database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.