USNO Analysis Report for Q23337 (20231203-q23337) This report is a contributed analysis report that does not correspond to the database maintained by the IVS Data Centers for this session. (Analyzed by Christopher Dieck, US Naval Observatory. Spoolfile source: interactive nuSolve analysis.) Problems: None. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 6 observation 17, WETTZELL:MK-VLBA , 2000+472, 07:52:41, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 21, WETTZELL:MK-VLBA , 2309+454, 08:02:50, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 22, WETTZELL:MK-VLBA , 0059+581, 08:04:23, quality code X: 9 S: 0, fringe code X: ' ' S: ' ' observation 35, WETTZELL:MK-VLBA , 2309+454, 08:24:20, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 36, WETTZELL:MK-VLBA , 0059+581, 08:25:50, quality code X: 9 S: 0, fringe code X: ' ' S: ' ' observation 39, WETTZELL:MK-VLBA , 1039+811, 08:29:32, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' Number of observations rejected during analysis: 1 observation 30, WETTZELL:MK-VLBA , 0759+183, 08:13:55, which fits at -11025.3 +/- 114.8 ps Other comments: None. Parameterization: 6 parameters: UT1 offset atmosphere offset for: MK-VLBA WETTZELL clock offset, first order term, and second order term for: MK-VLBA Clock breaks: None Session Statistics Observations: 39 scheduled 39 correlated (included in the database) 33 recoverable (usable in Solve/nuSolve) 32 used Session fit: 71.861 ps UT1 formal error: 13.36 microsec Source Performance Number of Observations Scheduled Correlated* Used 0016+731 2 2 2 0059+581 2 2 0 0345+460 1 1 1 0552+398 2 2 2 0602+673 2 2 2 0613+570 2 2 2 0642+449 2 2 2 0723+219 3 3 3 0729+259 3 3 3 0738+491 2 2 2 0743+277 3 3 3 0748+126 2 2 2 0759+183 1 1 0 0805+410 1 1 1 0814+425 1 1 1 0827+243 1 1 1 1039+811 1 1 0 2000+472 2 2 1 3C418 1 1 1 2113+293 1 1 1 2229+695 2 2 2 2309+454 2 2 0 ------------ --------- ---------- ------ Source Total 39 39 32 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.