USNO Analysis Report for Q23070 (20230311-q23070) This report is a contributed analysis report that does not correspond to the database maintained by the IVS Data Centers for this session. (Analyzed by Christopher Dieck, US Naval Observatory. Spoolfile source: interactive nuSolve analysis.) Problems: MK-VLBA is still out of service and did not observe. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 4 observation 3, ISHIOKA :WETTZELL, 1039+811, 07:32:22, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 19, ISHIOKA :WETTZELL, 1039+811, 07:51:19, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 35, ISHIOKA :WETTZELL, 1039+811, 08:10:14, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' observation 52, ISHIOKA :WETTZELL, 1039+811, 08:29:43, quality code X: 0 S: 9, fringe code X: ' ' S: ' ' Number of observations rejected during analysis: 2 observation 5, ISHIOKA :WETTZELL, 1144+402, 07:34:33, which fits at -2471.9 +/- 43.5 ps observation 48, ISHIOKA :WETTZELL, 0552+398, 08:24:51, which fits at -190.7 +/- 36.2 ps Other comments: None. Parameterization: 6 parameters: UT1 offset atmosphere offset for: ISHIOKA WETTZELL clock offset, first order term, and second order term for: ISHIOKA Clock breaks: None Session Statistics Observations: 82 scheduled (from all stations---includes MK-VLBA) 52 scheduled (from available stations---does not include MK-VLBA) 52 correlated (included in the database) 48 recoverable (usable in Solve/nuSolve) 46 used Session fit: 34.580 ps UT1 formal error: 6.20 microsec Source Performance Number of Observations Scheduled Correlated* Used 0003-066 1 1 1 0016+731 4 4 4 0059+581 3 3 3 0119+115 3 3 3 0133+476 2 2 2 0202+319 3 3 3 0235+164 3 3 3 0552+398 3 1 0 0613+570 3 3 3 0642+449 6 2 2 1039+811 12 4 0 1128+385 7 3 3 1144+402 9 3 2 1803+784 9 3 3 3C371 3 3 3 2000+472 1 1 1 3C418 3 3 3 2113+293 1 1 1 2229+695 3 3 3 2318+049 3 3 3 ------------ --------- ---------- ------ Source Total 82 52 46 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.