BKG Analysis Report for I23362 (20231228-i23362) This report is a contributed analysis report that does not correspond to the database maintained by the IVS Data Centers for this session. (Analyzed by Gerald Engelhardt, Federal Agency for Cartography and Geodesy (BKG), Spoolfile source: interactive nuSolve analysis.) Problems: None. Number of observations rejected during correlation: 0 Number of observations not usable by the software: 2 observation 7, 1929+226, KOKEE :WETTZELL, 17:44:14, quality codes - S:9, X:0 observation 18, 1039+811, KOKEE :WETTZELL, 18:14:34, quality codes - S:9, X:0 Number of observations rejected during analysis: 3 observation 15, KOKEE :WETTZELL, NRAO512, 18:07:00, which fits at -508.9 +/- 57.9 ps observation 17, KOKEE :WETTZELL, 1418+546, 18:11:51, which fits at -261.4 +/- 61.0 ps observation 19, KOKEE :WETTZELL, 2353+816, 18:17:10, which fits at 197.1 +/- 75.3 ps Other comments: Correlator TIMETAG: 2023/12/28 19:37:51. Parameterization: 6 parameters: UT1 offset atmosphere offset for: KOKEE WETTZELL clock offset (0), first order term (1), and/or second order term (2) for: WETTZELL (0,1,2) Clock breaks: None. ----------------------------------------- Session Statistics Observations: 24 scheduled (correlation report not supported) 24 correlated (included in database) 22 recoverable (usable in Solve/nuSolve) 19 used Session fit: 48.535 ps UT1 formal error: 11.950 microsec ----------------------------------------- Source Performance Number of Observations Scheduled(*) Correlated* Used 0602+673 1 1 1 0642+449 1 1 1 0716+714 1 1 1 0723+219 1 1 1 0955+476 2 2 2 1039+811 1 1 0 1053+704 1 1 1 1342+662 1 1 1 1418+546 2 2 1 1636+473 1 1 1 1732+389 1 1 1 1751+288 1 1 1 1806+456 1 1 1 1846+322 1 1 1 1929+226 1 1 0 2000+472 1 1 1 2229+695 2 2 2 2353+816 1 1 0 3C371 1 1 1 NRAO512 2 2 1 ------------ --------- ---------- ------ Source Total 24 24 19 * Correlated means included in the database. (*) All possible observations on scheduled network. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.