IVS Analysis Report for V22039 ($22FEB08VI) This report is the official IVS analysis report that corresponds to the database maintained by the IVS Data Centers for this session. (Analyzed by Sergei Bolotin, NVI, Inc. / NASA Goddard Space Flight Center. Spoolfile source: interactive solve/nuSolve analysis.) Problems: From the correlator report: "Unable to generate new phase corrections. Used phase corrections from 24-hour VGOS observations. KOKEE12M Used phase corrections from vo1259 WETTZ13S Used phase corrections from vo1315." Number of observations rejected during correlation: 0 Number of observations not usable by the software: 0 Number of observations rejected during analysis: 1 observation 59, KOKEE12M:WETTZ13S, 1039+811, 19:24:17, which fits at -128.9 +/- 42.7 ps Other comments: None. Parameterization: 6 parameters: UT1 offset atmosphere offset for: KOKEE12M WETTZ13S clock offset, first order term, and second order term for: WETTZ13S Clock breaks: None Session statistics Observations: 63 scheduled 63 correlated (included in the database) 63 recoverable (usable in Solve/nuSolve) 62 used Session fit: 40.739 ps UT1 formal error: 4.47 microsec Source Performance Number of Observations Scheduled Correlated* Used 0016+731 4 4 4 0059+581 2 2 2 0718+793 4 4 4 1039+811 5 5 4 1053+704 1 1 1 1123+264 1 1 1 1145+268 2 2 2 1306+360 4 4 4 1308+328 2 2 2 1418+546 2 2 2 1803+784 4 4 4 1842+681 5 5 5 1849+670 3 3 3 2000+472 5 5 5 2113+293 1 1 1 2214+350 6 6 6 2215+150 1 1 1 2309+454 6 6 6 2319+317 5 5 5 ------------ --------- ---------- ------ Source Total 63 63 62 * Correlated means included in database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.