==================================== rd2207 ==================================== Ma : Motor alarm (11:37-12:19). Feed mylar broke during thunderstorm. Halted 13:26. T6 : No log. No problems found for : Hh, Kk, Ns, Ny, On, Wz ================================ rd2207hh READY ================================ 2022-08-10 14:25:39 rd2207, HartRAO, Ready-message Session rd2207 ready message for HartRAO. ----------------------------------------- Comments: HartRAO is ready to start RD2207. All systems are nominal. Session is being operated remotely. First source: 1633+38 at 18:00:00 UT FMOUT-GPS: 6.4332 microseconds Wx: Temperature (C): 21.5 Pressure (mBar): 866.3 Humidity (%): 34.8 Sky Conditions: Clear Cable difference is: longer cable makes the reading smaller by 543.9 microseconds and is nominal Pointing values: na Tsys (x1/s/x2): 53.9/na/50.4 ================================ rd2207hh START ================================ 2022-08-10 18:00:01 rd2207, HartRAO, Autostart-message Session rd2207 auto-start message for HartRAO. ---------------------------------------------- Started recording with source: 1633+38 at 222.18:00:00 UT ================================ rd2207hh STOP ================================= 2022-08-11 17:55:43 rd2207, HartRAO, Stop-message Session rd2207 stop message for HartRAO. ---------------------------------------- Comments: HartRAO has completed RD2207. All scans recorded successfully. Weather conditions were clear throughout. Data will be e-shipped to Shanghai. Disk Inventory: A 0, B 2, C 0, D 1, E 1, F 0, G 4, H 0, (other larger) 6 Observation finished at: 17:53:42 UT ================================ rd2207kk READY ================================ 2022-08-10 17:38:38 rd2207, Kokee Park 20m, Ready-message Session rd2207 ready message for Kokee Park 20m. ------------------------------------------------ First source: 0014+813 at 222/1806:49 UT FMOUT-GPS: +9.64 microseconds Wx: Temperature (C): 17.3 Pressure (mBar): 891 Humidity (%): 89.2 Sky Conditions: clear sky Cable difference is: longer cable makes the reading smaller by 52.5 microseconds and is nominal Pointing values: SEFD X/S Source Az/El Offset1 Offset2 2137/789 casa 326/29 0.013 -0.002 1926/969 taurusa 86/69 -0.020 -0.003 Tsys (x1/s/x2): 79/32/47 ================================ rd2207kk START ================================ 2022-08-10 18:06:49 rd2207, Kokee Park 20m, Autostart-message Session rd2207 auto-start message for Kokee Park 20m. ----------------------------------------------------- Started recording with source: 0014+813 at 222.18:06:49 UT ================================ rd2207kk STOP ================================= 2022-08-11 18:14:21 rd2207, Kokee Park 20m, Stop-message Session rd2207 stop message for Kokee Park 20m. ----------------------------------------------- Comments: Diskpack USN-0095 will be sennt out via FedEx AWB# 7776 2560 1643. Observation finished at: 223/1756:58 UT ================================ rd2207ma READY ================================ 2022-08-10 08:38:48 RD2207, MATERA, Ready-message Session RD2207 ready message for MATERA. ---------------------------------------- First source: 1633+38 at 18:00:00 UT GPS-FMOUT: 4.281 microseconds Wx: Temperature (C): 27.4 Pressure (mBar): 960.7 Humidity (%): 47.7 Sky Conditions: CLEAR SKY Cable difference is: longer cable makes the reading smaller by 260.7 microseconds and is nominal Pointing values: SEFD X/S Source Az/El Offset1 Offset2 1527/1394 CASA 327/26 -0.0004 0.0007 Tsys (x1/s/x2): 61/274/0 ================================ rd2207ma START ================================ 2022-08-10 18:00:25 rd2207, MATERA, Start-message Session rd2207 start message for MATERA. ---------------------------------------- Started recording with source: 1633+38 at: 18:00:00 UT ================================== rd2207ma =================================== 2022-08-11 13:47:08 Matera halted RD2207 and will not run R41063 Matera halted RD2207 because the feed mylar broke during thunderstorm. For the same reason, Matera will not run next upcoming R41063 Regards, Pino [e-GEOS S.p.A.] Giuseppe Colucci Matera Space Center Operations Contrada Terlecchie - 75100 Matera - Italy Ph: +39 0835 377 574 | Fax: +39 06 4099-9941 giuseppe.colucci@e-geos.it -WARNING: This message contains confidential and/or proprietary information which may be subject to privilege or immunity and which is intended for the use of its addressee only. Should you receive this message in error, you are kindly requested to inform the sender and to definitively remove it from any paper or electronic format. Any other use of this e-mail is strictly forbidden. Thank you in advance for your cooperation. Please consider the environment before printing this e-mail. ================================ rd2207ns READY ================================ 2022-08-10 17:50:06 rd2207, Ny-Alesund 13m NS, Ready-message Session rd2207 ready message for Ny-Alesund 13m NS. --------------------------------------------------- First source: 1633+38 at 18:00 UT FMOUT-GPS: 23,792 microseconds Wx: Temperature (C): 7,5 Pressure (mBar): 999,1 Humidity (%): 80 Sky Conditions: partlu cloudy Cable difference is: na Pointing values: na Tsys values: na ================================ rd2207ns START ================================ 2022-08-10 18:00:10 rd2207, Ny-Alesund 13m NS, Autostart-message Session rd2207 auto-start message for Ny-Alesund 13m NS. -------------------------------------------------------- Started recording with source: 1633+38 at 222.18:00:00 UT ================================ rd2207ns STOP ================================= 2022-08-11 18:19:26 rd2207, Ny-Alesund 13m NS, Stop-message Session rd2207 stop message for Ny-Alesund 13m NS. -------------------------------------------------- Disk Inventory: A 0, B 0, C 0, D 6, E 0, F 0, G 1, H 0, (other larger) 14 Observation finished at: 17:59:39 UT ================================ rd2207ny READY ================================ 2022-08-10 17:42:54 rd2207, Ny-Alesund, Ready-message Session rd2207 ready message for Ny-Alesund. -------------------------------------------- First source: 1633+38 at 18:00 UT GPS-FMOUT: -3,28 microseconds Wx: Temperature (C): 11 Pressure (mBar): 994,1 Humidity (%): 72 Sky Conditions: partly cloudy Cable difference is: longer cable makes the reading larger by 658 microseconds and is nominal Pointing values: na Tsys values: na ================================ rd2207ny START ================================ 2022-08-10 18:00:00 rd2207, Ny-Alesund, Autostart-message Session rd2207 auto-start message for Ny-Alesund. ------------------------------------------------- Started recording with source: 1633+38 at 222.18:00:00 UT ================================ rd2207ny STOP ================================= 2022-08-11 18:25:26 rd2207, Ny-Alesund, Stop-message Session rd2207 stop message for Ny-Alesund. ------------------------------------------- Disk Inventory: A 0, B 0, C 0, D 6, E 0, F 0, G 1, H 0, (other larger) 14 Observation finished at: 17:59:25 UT ================================ rd2207on READY ================================ 2022-08-10 15:15:09 RD2207, ready message, ONSALA60 RD2207 ready message for ONSALA60 weather, clock and first source: 2022.222.15:08:24.75;wx 2022.222.15:08:24.75/wx/19.9,1025.8,73.9,5.0,173.0 2022.222.15:08:28.69;clock 2022.222.15:08:28.69&clock/"fmout-gps=cb 2022.222.15:08:28.70&clock/gps-fmout=cb 2022.222.15:08:28.70#ibcon#Opening socket to network device at 192.165.6.233 port 1234 ... 2022.222.15:08:29.02#ibcon#Closing network connection after successful communication 2022.222.15:08:29.02/gps-fmout/+8.101482E-05 2022.222.15:08:31.19;source 2022.222.15:08:31.19/source/casa,232324.800,584859.00,2000.0000,,232427.217,585614.72,2022.6082 /Periklis ================================ rd2207on START ================================ 2022-08-10 18:06:19 RD2207, start message, ONSALA60 ONSALA60 started observing for RD2207 as scheduled. /Periklis ================================ rd2207on STOP ================================= 2022-08-11 18:07:38 RD2207, stop message, ONSALA60 RD2207 stop message for ONSALA60 One minor data loss 2022.223.08:01:12.10/fb/!evlbi? 0 : total : 9088306 : loss : 507178 ( 5.29%) : out-of-order : 0 ( 0.00%) : extent : 0seqnr/pkt ; No other known issues /Periklis ================================ rd2207t6 START ================================ 2022-08-10 18:04:22 rd2207,Tianma,startmessage Dear colleagues Tianma Station has started rd2207 in DBBC2 mode. The first source was 1633+38(222-1800,#7)at 18:00:00 UT. Weather conditions: overcast. Clock offset=Fmout-GPS= 81.005 us at 18:00:00 UT. All systems are normal. Tianma65m VLBI Team ================================================================================