Starting generation of Calibration File FS version = 0009.0011.0008 time_zero = 15426000 Found #1552 errors of type = ERROR ib -4 GPIB Device time-out on response ca Found #564 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #560 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #514 errors of type = ERROR ch -308 vc total power integrator overflow Found #308 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #246 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #131 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #121 errors of type = ERROR ch -308 ve total power integrator overflow Found #66 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #64 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #46 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #36 errors of type = ERROR ch -308 v5 total power integrator overflow Found #36 errors of type = ERROR ch -308 v1 total power integrator overflow Found #31 errors of type = ERROR ch -309 vb alarm is on Found #26 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #22 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #9 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #5 errors of type = ERROR fl -1 Previous source in this schedule not reached before new source was commanded Found #4 errors of type = ERROR qn -201 Error in request. Unknown module or does not match your equipment. Found #4 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #4 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #1 errors of type = ERROR m5 -902 MARK5 return code 2: command not implemented or not relevant to this DTS Found #1 errors of type = ERROR m5 -900 : Must have Mark-5B DIM Found #1 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found these BBCs: vc06 vc11 NBBC: 2 Found these RX parameters: 00(front) 01(rear) 02(lo) RX1 min= 13.37 max= 22.28 RX2 min= 22.28 max= 32.78 RX3 min= 39.13 max= 46.58 Plotting 2 Tsys channels: 06 11 Tsys values are: 1 2 3 etc NTSYS: 2 in match_chan ft1= rd1706ho.log.tsy1.ntup nt1= 20 st1= 6u tt= 1 set scale tsys1 [2] min max 63.0 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 55 ymax 305 in match_chan ft1= rd1706ho.log.tsy1.ntup nt1= 14 st1= bu tt= 1 set scale tsys1 [2] min max 63.0 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 11.4 ymax 305