Starting generation of Calibration File FS version = 0009.0011.0019 time_zero = 4464000 Found #56 errors of type = ERROR st -7 Antenna off-source! Found #52 errors of type = ERROR qk -211 Tsys value for device ib overflowed or was less than zero. Found #48 errors of type = ERROR qk -211 Tsys value for device ia overflowed or was less than zero. Found #43 errors of type = ERROR qk -211 Tsys value for device ic overflowed or was less than zero. Found #26 errors of type = ERROR qk -211 Tsys value for device 1l overflowed or was less than zero. Found #24 errors of type = ERROR qk -211 Tsys value for device 1u overflowed or was less than zero. Found #12 errors of type = ERROR m5 -104 mk5cn: time-out connection closed Found #9 errors of type = ERROR qk -211 Tsys value for device 2u overflowed or was less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device 9u overflowed or was less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device au overflowed or was less than zero. Found #7 errors of type = ERROR qk -211 Tsys value for device eu overflowed or was less than zero. Found #7 errors of type = ERROR qk -211 Tsys value for device bu overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device cu overflowed or was less than zero. Found #5 errors of type = ERROR qk -211 Tsys value for device du overflowed or was less than zero. Found #4 errors of type = ERROR m5 -904 MARK5 return code 4: error encountered (during attempt to execute) Found #4 errors of type = ERROR st -4 Interface not set to remote. Found #4 errors of type = ERROR fl -1 Previous source in this schedule not reached before new source was commanded Found #4 errors of type = ERROR st -6 Antenna control restored. Found #3 errors of type = ERROR fv -8 fmset: Error from MK5CN please see messages above. Found #3 errors of type = ERROR 5k 302 There have not been two scan_name ... commands since the schedule started use scan_check force to force check Found #3 errors of type = ERROR m5 -900 : The DOT clock is not set (use dot_set ...) Found #3 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #2 errors of type = ERROR m5 -900 : mk5command status.cc 96 in [std::string status_fn(bool const std::vector std::allocator > std::allocator std::allocator > > > runtime )] ::XLRGetBankStatus(rte.xlrdev.sshandle() BANK_A bs[0]) fails - Device command failed execution (103) Found #2 errors of type = ERROR m5 -900 : mk5command bankinfoset.cc 117 in [std::string bankinfoset_fn(bool const std::vector std::allocator > std::allocator std::allocator > > > runtime )] ::XLRGetBankStatus(GETSSHANDLE(rte) BANK_A bs[0]) fails - Device command failed execution (103) Found #2 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #2 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #2 errors of type = ERROR st -994 No new wx data since last report Found #1 errors of type = ERROR qk -211 Tsys value for device 4u overflowed or was less than zero. Found #1 errors of type = ERROR m5 -114 mk5cn: re-open after pre-drain error was okay proceeding to transaction. Found #1 errors of type = ERROR qk -211 Tsys value for device 3u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 5u overflowed or was less than zero. Found #1 errors of type = ERROR m5 -112 mk5cn: EOF pre-draining input mark 5 may have crashed connection closed Found #1 errors of type = ERROR qk -211 Tsys value for device 6u overflowed or was less than zero. Found these BBCs: NBBC: 0 Found these SK parameters: get get get RX1 min= 100000 max= 2017.051.16:30:04.16 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: Tsys values are: -1 1 2 etc NTSYS: 0