Starting generation of Calibration File FS version = 0009.0011.0018 time_zero = 2134800 Found #90 errors of type = ERROR st -7 Antenna off-source! Found #43 errors of type = ERROR qk -211 Tsys value for device ic overflowed or was less than zero. Found #26 errors of type = ERROR qk -211 Tsys value for device ib overflowed or was less than zero. Found #23 errors of type = ERROR qk -211 Tsys value for device 1l overflowed or was less than zero. Found #18 errors of type = ERROR qk -211 Tsys value for device 1u overflowed or was less than zero. Found #14 errors of type = ERROR qk -211 Tsys value for device ia overflowed or was less than zero. Found #9 errors of type = ERROR qk -211 Tsys value for device 9u overflowed or was less than zero. Found #7 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #7 errors of type = ERROR qk -211 Tsys value for device au overflowed or was less than zero. Found #7 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #4 errors of type = ERROR qk -211 Tsys value for device eu overflowed or was less than zero. Found #3 errors of type = ERROR qk -211 Tsys value for device bu overflowed or was less than zero. Found #3 errors of type = ERROR st -4 Interface not set to remote. Found #3 errors of type = ERROR st -6 Antenna control restored. Found #2 errors of type = ERROR qk -211 Tsys value for device cu overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device 2u overflowed or was less than zero. Found #2 errors of type = ERROR fl -1 Previous source in this schedule not reached before new source was commanded Found #1 errors of type = ERROR qk -211 Tsys value for device du overflowed or was less than zero. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8l. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8l. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 5u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector ia. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector ia. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1l. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 8u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 6u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 7u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector ib. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 4u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 3u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 2u. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector ib. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 1l. Found #1 errors of type = ERROR nf -7 WARNING: Source structure correction greater than 20% for detector 1u. Found #1 errors of type = ERROR q1 -307 WARNING: Source structure correction greater than 20% for detector 2u. Found these BBCs: NBBC: 0 Found these SK parameters: get get get RX1 min= 100000 max= 2017.024.17:30:05.18 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: Tsys values are: -1 1 2 etc NTSYS: 0