IVS Analysis Report for J17324 ($17NOV20XK) This report is the official IVS analysis report that corresponds to the database maintained by the IVS Data Centers for this session. (Analyzed by Karen Baver, Goddard Space Flight Center VLBI Analysis Center. Spoolfile source: interactive solve/nuSolve analysis.) Problems: None. Number of observations rejected during correlation: 2 SESHAN25:WETTZ13N, 1351-018, 07:05:58 --- not correlated in X-band WETTZ13N:WETTZELL, 1418+546, 07:23:46 --- not correlated in S-band Number of observations not usable by the software: 8 observation 37, SESHAN25:WETTZ13N, NRAO512 , 07:18:16, quality code X-band: 0 S-band: 0 observation 40, NYALES20:WETTZ13N, NRAO512 , 07:18:16, quality code X-band: 0 S-band: 0 observation 115, SESHAN25:WETTZ13N, 1751+288, 07:50:44, quality code X-band: 0 S-band: 0 observation 118, NYALES20:WETTZ13N, 1751+288, 07:50:44, quality code X-band: 0 S-band: 0 observation 127, SESHAN25:WETTZ13N, 1923+210, 07:54:43, quality code X-band: 0 S-band: 0 observation 130, NYALES20:WETTZ13N, 1923+210, 07:54:43, quality code X-band: 0 S-band: 0 observation 139, SESHAN25:WETTZ13N, NRAO512 , 07:59:37, quality code X-band: 0 S-band: 0 observation 142, NYALES20:WETTZ13N, NRAO512 , 07:59:37, quality code X-band: 0 S-band: 0 Number of observations rejected during analysis: 25 observation 7, SESHAN25:WETTZELL, 1351-018, 07:05:58, which fits at -223.2 +/- 32.7 ps observation 8, NYALES20:SESHAN25, 1351-018, 07:05:58, which fits at 258.8 +/- 37.9 ps The WETTZ13N:WETTZELL baseline was deselected according to standard procedures at the GSFC VLBI Analysis Center. This deselected 23 observations; one observation was not correlated. Other comments: The correlator provided the following station notes: NYALES20 (Ny/N): Clock in logfile is wrong. SESHAN25 (Sh/C): Ok. WETTZ13N (Wn/W): Several non-detections in both bands. WETTZELL (Wz/V): Ok. Parameterization: 14 parameters: UT1 offset atmosphere offset for: NYALES20 SESHAN25 WETTZ13N WETTZELL clock offset, first order term, and second order term for: SESHAN25 WETTZ13N WETTZELL Clock breaks: None Session Statistics Observations: 144 scheduled 142 correlated (included in the database) 134 recoverable (usable in Solve/nuSolve) 109 used Session fit: 33.369 ps UT1 formal error: 5.64 microsec Source Performance Number of Observations Scheduled Correlated* Used 0059+581 6 6 5 0133+476 6 6 5 0602+673 6 6 5 1300+580 6 6 5 1351-018 6 5 2 1418+546 6 5 5 1606+106 6 6 5 NRAO512 12 12 6 1749+096 6 6 5 1923+210 6 6 3 1846+322 6 6 5 2000+472 6 6 5 1144+402 6 6 5 1546+027 6 6 5 1617+229 12 12 10 1705+018 6 6 5 0016+731 6 6 5 1555+001 6 6 5 1039+811 6 6 5 1538+149 6 6 5 1751+288 6 6 3 1849+670 6 6 5 ------------ --------- ---------- ------ Source Total 144 142 109 * Correlated means included in the database. Please note that the number of recoverable (usable) observations cannot be broken down by source for Intensive solutions.