Starting generation of Calibration File FS version = 0009.0011.0008 time_zero = 11746800 Found #313 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #313 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #285 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #161 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #108 errors of type = ERROR ch -308 vd total power integrator overflow Found #86 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #47 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #18 errors of type = ERROR qk -211 Tsys value for device vb overflowed or was less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #6 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #5 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #5 errors of type = ERROR ch -308 ve total power integrator overflow Found #4 errors of type = ERROR ch -309 v4 alarm is on Found #4 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #4 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #4 errors of type = ERROR ch -309 vb alarm is on Found #2 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or was less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or was less than zero. Found #1 errors of type = ERROR m5 -900 : Check formatter serial number even Found #1 errors of type = ERROR m5 -902 MARK5 return code 2: command not implemented or not relevant to this DTS Found #1 errors of type = ERROR m5 -900 : Must have Mark-5B DIM Found #1 errors of type = ERROR ch -308 v5 total power integrator overflow Found #1 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #1 errors of type = ERROR ch -308 v6 total power integrator overflow Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found these BBCs: vc06 vc11 NBBC: 2 Found these RX parameters: 00(front) 01(rear) 02(lo) RX1 min= 13.98 max= 21.91 RX2 min= 25.09 max= 34.98 RX3 min= 40.59 max= 47.92 Plotting 2 Tsys channels: 06 11 Tsys values are: 1 2 3 etc NTSYS: 2 in match_chan ft1= crf101ho.log.tsy1.ntup nt1= 20 st1= 6u tt= 1 set scale tsys1 [2] min max 65.2 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 62.7 ymax 305 in match_chan ft1= crf101ho.log.tsy1.ntup nt1= 14 st1= bu tt= 1 set scale tsys1 [2] min max 65.2 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 18 ymax 305