Starting generation of Calibration File FS version = 0009.0011.0019 time_zero = 28854000 Found #97 errors of type = ERROR st -816 sxcheck tbox is 30.371. (should be 17.000 to 30.000) Found #11 errors of type = ERROR st -7 Antenna off-source! Found #6 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #6 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #3 errors of type = ERROR st -4 Interface not set to remote. Found #3 errors of type = ERROR st -6 Antenna control restored. Found #2 errors of type = ERROR qk -211 Tsys value for device ib overflowed or was less than zero. Found #1 errors of type = ERROR mc -2 Interface b2 responded but did not ACKnowledge. Found #1 errors of type = ERROR st -823 sxcheck sup is 222.277. (should be 230.000 to 315.000) Found #1 errors of type = ERROR ch -208 b2 gain mode does not check with requested setting Found #1 errors of type = ERROR ch -212 b4 LO unlocked. Found #1 errors of type = ERROR st -823 sxcheck sup is 225.208. (should be 230.000 to 315.000) Found #1 errors of type = ERROR st -823 sxcheck sup is 227.162. (should be 230.000 to 315.000) Found #1 errors of type = ERROR st -823 sxcheck sup is 223.254. (should be 230.000 to 315.000) Found #1 errors of type = ERROR st -823 sxcheck sup is 178.310. (should be 230.000 to 315.000) Found #1 errors of type = ERROR st -823 sxcheck sup is 218.368. (should be 230.000 to 315.000) Found #1 errors of type = ERROR st -823 sxcheck sup is 225.696. (should be 230.000 to 315.000) Found #1 errors of type = ERROR st -823 sxcheck sup is 167.562. (should be 230.000 to 315.000) Found #1 errors of type = ERROR qk -211 Tsys value for device au overflowed or was less than zero. Found #1 errors of type = ERROR mc -2 Interface b8 responded but did not ACKnowledge. Found #1 errors of type = ERROR st -823 sxcheck sup is 218.857. (should be 230.000 to 315.000) Found #1 errors of type = ERROR 5k 302 There have not been two scan_name ... commands since the schedule started use scan_check force to force check Found #1 errors of type = ERROR st -823 sxcheck sup is 201.270. (should be 230.000 to 315.000) Found #1 errors of type = ERROR ch -212 bd LO unlocked. Found these BBCs: bbc01 bbc05 bbc09 NBBC: 3 Found these SX parameters: slo xlo sup RX1 min= 3.83 max= 3.92 RX2 min= 4.67 max= 4.80 RX3 min= 248.17 max= 263.31 Plotting 3 Tsys channels: 01 05 09 Tsys values are: -1 1 2 etc NTSYS: 3 in match_chan ft1= c1703kk.log.tsy1.ntup nt1= 8 st1= 1u tt= 1 set scale tsys1 [2] min max 77.1 219.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 72.3 ymax 228.1 in match_chan ft1= c1703kk.log.tsy1.ntup nt1= 20 st1= 5u tt= 1 set scale tsys1 [2] min max 77.1 219.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 44.5 ymax 150.5 in match_chan ft1= c1703kk.log.tsy1.ntup nt1= 13 st1= 9u tt= 1 set scale tsys1 [2] min max 77.1 219.4 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 16.1 ymax 195.4