Starting generation of Calibration File FS version = 0009.0010.0004 time_zero = 27878400 Found #677 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #137 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #117 errors of type = ERROR ch -308 vd total power integrator overflow Found #90 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or was less than zero. Found #71 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or was less than zero. Found #61 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #21 errors of type = ERROR qk -211 Tsys value for device vd overflowed or was less than zero. Found #20 errors of type = ERROR sc -2 setcl: formatter time out-of-range Found #19 errors of type = ERROR ma -3 Unrecognized device Found #18 errors of type = ERROR bo -129 Error in new proc routine stack is flushed. FMP FFF Found #17 errors of type = ERROR ch -309 v4 alarm is on Found #17 errors of type = ERROR ch -309 vd alarm is on Found #17 errors of type = ERROR ch -309 vc alarm is on Found #15 errors of type = ERROR ch -301 v1 module is not in remote Found #9 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #8 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #7 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #7 errors of type = ERROR qk -211 Tsys value for device va overflowed or was less than zero. Found #7 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or was less than zero. Found #7 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or was less than zero. Found #7 errors of type = ERROR ch -308 ve total power integrator overflow Found #6 errors of type = ERROR qk -302 Found #6 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #3 errors of type = ERROR bo -133 Error opening procedure library Found #3 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #2 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #1 errors of type = ERROR m5 -900 Check formatter serial number even Found #1 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #1 errors of type = ERROR bo -309 Help not available for that command maybe your equipment type is wrong. Found these BBCs: NBBC: 0 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 0 Tsys channels: Tsys values are: 1 2 -1 etc NTSYS: 0