Starting generation of Calibration File FS version = 0009.0007.0007 time_zero = 22158000 Found #494 errors of type = ERROR qk -211 Tsys value for device ve overflowed or was less than zero. Found #132 errors of type = ERROR AN -4 Interface not set to remote. Found #68 errors of type = ERROR st -100 Waiting for antenna response timed out - antenna protocol error. Found #66 errors of type = ERROR st -999 Antenna STOP command failed!!! Found #40 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #40 errors of type = ERROR st -999 Error in antenna communication Found #33 errors of type = ERROR st -999 Failed: closing antenna communication Found #18 errors of type = ERROR st -999 Failed: stopping antenna motion Found #15 errors of type = ERROR st -999 Failed: processing new source Found #10 errors of type = ERROR st -100 invalid time in antenna message - antenna protocol error. Found #7 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #6 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #3 errors of type = ERROR ch -308 vc total power integrator overflow Found #2 errors of type = ERROR m5 -906 MARK5 return code 6: inconsistent or conflicting request Found #2 errors of type = ERROR ch -308 v1 total power integrator overflow Found #2 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or was less than zero. Found #2 errors of type = ERROR st -999 Failed: opening antenna communication Found #2 errors of type = ERROR m5 -904 MARK5 return code 4: error encountered (during attempt to execute) Found #2 errors of type = ERROR ch -312 IF1 attenuator does not check with requested value Found #2 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or was less than zero. Found #1 errors of type = ERROR m5 -900 Can't get SS version Found #1 errors of type = ERROR ch -308 va total power integrator overflow Found #1 errors of type = ERROR ch -362 IF3 attenuator does not check with requested value. Found #1 errors of type = ERROR ch -313 IF2 attenuator does not check with requested value Found #1 errors of type = ERROR qs -102 No default for right ascension. Found #1 errors of type = ERROR ch -308 v2 total power integrator overflow Found #1 errors of type = ERROR m5 -900 Can't get device info Found #1 errors of type = ERROR m5 -900 Previous recording still active Found #1 errors of type = ERROR st -100 wrong OK STOP message - antenna protocol error. Found #1 errors of type = ERROR sp -3 More than 12 characters in function or procedure name. Found #1 errors of type = ERROR m5 -900 Data transfer in progress Found #1 errors of type = ERROR bo -133 Error opening procedure library Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these parameters: RX1 min= 100000 max= -1 RX2 min= 100000 max= -1 RX3 min= 100000 max= -1 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= r4241sv.log.tsy1.ntup nt1= 7 st1= 1u tt= 1 set scale tsys1 [2] min max 26.7 41.5 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 25.9 ymax 47.5 in match_chan ft1= r4241sv.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 26.7 41.5 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 38.9 ymax 68.2 in match_chan ft1= r4241sv.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 26.7 41.5 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 81.8 ymax 305