Starting generation of Calibration File FS version = 0009.0007.0006 time_zero = 14929200 Found #125 errors of type = ERROR sp -13 This command not supported for your equipment check equip.ctl. Found #125 errors of type = ERROR DA -81 ERR_WR_RD_REG: Wr Rd reg check failed Found #118 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #118 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #4 errors of type = ERROR rt -201 Position must be a number "reset" "unk" or "uns". Found #2 errors of type = ERROR ma -4 Device rx timed-out on response. Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #2 errors of type = ERROR rl -321 Unknown rcl device da Found #1 errors of type = ERROR RL -138 No connection open for that reference address on device r1 Found #1 errors of type = ERROR qk -211 Tsys value for device 2u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 3u overflowed or was less than zero. Found #1 errors of type = ERROR rz -25 EF- STAT_TRANBADVOLT: Transport 4-7 +5V -5V supply is bad (check C4 cable).\n Found #1 errors of type = ERROR qk -211 Tsys value for device 4u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 5u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 6u overflowed or was less than zero. Found #1 errors of type = ERROR rl -140 Network connection closed by remote host on device r1 Found #1 errors of type = ERROR qk -211 Tsys value for device 8u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 9u overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device eu overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device du overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device cu overflowed or was less than zero. Found #1 errors of type = ERROR rz -3 EFC STAT_DIAGFAIL: Diagnostic test failed diag error code 109:\nDIAG_SYNCBYPASS: Channels 0-7 are missing L2 sync in transport bypass path.\nProbable bad module: Transport(s) cables. Possible bad module: DRD or FORM.\nCheck that the C3 and C4 cables are properly connected. Check the bypass\npath of the aff\n Found #1 errors of type = ERROR rz -45 E-C STAT_TRANSYNCERR32: Transport(s) 1-5 have had 32 Hz sync errors.\n Found #1 errors of type = ERROR rz -26 EF- STAT_TRANBADRECSIG: Transport 0-7 record clk data is bad (check C3 cable).\n Found #1 errors of type = ERROR rz -12 EF- STAT_TRANFAIL: Transport 0-7 failure (reason follows).\n Found #1 errors of type = ERROR bo -304 This error already in TNX list so it is already 'off'. Found #1 errors of type = ERROR rz -45 E-C STAT_TRANSYNCERR32: Transport(s) 1-7 have had 32 Hz sync errors.\n Found #1 errors of type = ERROR rz -25 occurred a total of 9 times but has now stopped Found #1 errors of type = ERROR rz -26 occurred a total of 8 times but has now stopped Found #1 errors of type = ERROR qk -211 Tsys value for device ia overflowed or was less than zero. Found #1 errors of type = ERROR RL -321 Unknown rcl device da Found #1 errors of type = ERROR rz -45 E-C STAT_TRANSYNCERR32: Transport(s) 3-7 have had 32 Hz sync errors.\n Found #1 errors of type = ERROR rz -45 occurred a total of 8 times but has now stopped Found #1 errors of type = ERROR DA -100 Undefined error code: -100 Found #1 errors of type = ERROR rz -12 occurred a total of 9 times but has now stopped Found #1 errors of type = ERROR qk -211 Tsys value for device au overflowed or was less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device bu overflowed or was less than zero. Found these BBCs: NBBC: 0 Found these SX parameters: slo xlo sup RX1 min= 3.73 max= 2006.172.19:46:17.68 RX2 min= 4.59 max= 4.69 RX3 min= 271.62 max= 278.94 Plotting 0 Tsys channels: Tsys values are: 1 2 3 etc NTSYS: 0