Starting generation of Calibration File FS version = 0009.0006.0002 time_zero = 29005200 Found #1739 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #222 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or was less than zero. Found #97 errors of type = ERROR ch -342 Tape is not in ready state (vacuum not ready) Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #80 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #80 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #80 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #80 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #80 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #80 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #80 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #80 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #80 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #80 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. Found #80 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #80 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #80 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #80 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #80 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #79 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. Found #79 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #77 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #56 errors of type = ERROR ch -309 vc alarm is on Found #56 errors of type = ERROR q -404 Head positioning failed to converge. Found #26 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or was less than zero. Found #24 errors of type = ERROR q< -301 Vacuum is not ready. Found #16 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #13 errors of type = ERROR qg -304 Track 13 sync errors exceed threshold. Found #8 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or was less than zero. Found #7 errors of type = ERROR ch -332 Tape drive is not in remote Found #7 errors of type = ERROR ch -308 v3 total power integrator overflow Found #6 errors of type = ERROR q -407 Head 2 reached limit or is stuck. Found #5 errors of type = ERROR qg -304 Track 11 sync errors exceed threshold. Found #5 errors of type = ERROR qg -304 Track 9 sync errors exceed threshold. Found #4 errors of type = ERROR ch -4 Device vc timed-out on response from MATCN Found #4 errors of type = ERROR qk -211 Tsys value for device vc overflowed or was less than zero. Found #3 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #3 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #3 errors of type = ERROR ch -302 vc frequency does not check with requested value Found #2 errors of type = ERROR ch -304 vc TPI selection does not check with requested setting Found #2 errors of type = ERROR ma -4 Device vc timed-out on response. Found #2 errors of type = ERROR ch -303 vc bandwidth does not check with requested value Found #2 errors of type = ERROR ch -306 vc LSB attenuator does not check with requested setting Found #2 errors of type = ERROR ch -305 vc USB attenuator does not check with requested setting Found #2 errors of type = ERROR ch -334 Tape should be moving and it's stopped Found #1 errors of type = ERROR qg -304 Track 7 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 23 sync errors exceed threshold. Found #1 errors of type = ERROR qg -304 Track 5 sync errors exceed threshold. Found #1 errors of type = ERROR ch -301 vc module is not in remote Found #1 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found these BBCs: vc01 vc05 vc09 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 44.99 max= 2004.335.17:13:31.48 RX2 min= 39.49 max= 43.28 RX3 min= 0.143 max= 0.147 Plotting 3 Tsys channels: 01 05 09 Tsys values are: 1 2 3 etc NTSYS: 3 in match_chan ft1= ohig34ft.log.tsy1.ntup nt1= 7 st1= 1u tt= 1 set scale tsys1 [2] min max 63.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 43 ymax 110.4 in match_chan ft1= ohig34ft.log.tsy1.ntup nt1= 19 st1= 5u tt= 1 set scale tsys1 [2] min max 63.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 55.5 ymax 115 in match_chan ft1= ohig34ft.log.tsy1.ntup nt1= 12 st1= 9u tt= 1 set scale tsys1 [2] min max 63.6 305 set scale tsys2 [2] min max set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 9.4 ymax 43.7