INT 203-193 / K03193 correlator report 2003 July 12 193/07:30-193/08:31 Tsukuba correlator, Japan Kyoichi Sakamoto, GSI/SED Co., Ltd. COMMENTS TSUKUB32(T-Ts): All scans were processed. There is no particular issues to report. Wettzell(V-Wz): All scans were processed. There is no particular issues to report. PF=3.0 STATION CLOCKS fmout-gps final clock drift clock drift [usec] [usec] [e-12sec] Ts 2.176 2.176 1.1236E-12 Wz -1.852 -1.902 1.4249E-12 PROCESS SUMMARY BY BASELINE/FREQUENCY Base 0 1 2 3 4 5 6 7 8 9 D G N - Tot TV X 0 0 0 0 0 0 1 1 3 15 0 0 0 0 20 TV S 0 0 0 0 0 1 2 0 2 15 0 0 0 0 20 Column Totals, numbers then percentages 0 0 0 0 0 1 3 1 5 30 0 0 0 0 40 % .0 .0 .0 .0 .0 2.5 7.5 --> --> 90.0 .0 .0 .0 .0100.0 QC = 0 : Fringes not detected. = 1-9 : Fringes detected. The higher number, the better quality. = D : No data in one or more frequency channels. = G : Fringe amp in a freq ch is <.5 times coherent amp only if snr>20. = N : No valid correlator data. = - : Not scanned Base Line: TV Total Obs: 20 Error : 0 % : .0 (ERROR: Q-code of either band is less than 4 or letter code, or not scanned) SNR histogram Distribution of X-band SNRs, for each baseline SNR: 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 >> TV: 0 0 0 0 1 0 0 0 2 0 0 0 0 0 0 2 2 13 Total 0 0 0 0 1 0 0 0 2 0 0 0 0 0 0 2 2 13 Total number of obs: 20 Average SNR: 93.8 Distribution of S-band SNRs, for each baseline SNR: 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 >> TV: 0 0 0 1 0 1 1 0 0 1 4 0 3 1 0 0 1 7 Total 0 0 0 1 0 1 1 0 0 1 4 0 3 1 0 0 1 7 Total number of obs: 20 Average SNR: 72.6