INT 203-179 / K03179 correlator report 2003 June 28 179/07:30-179/08:31 Tsukuba correlator, Japan Kyoichi Sakamoto, GSI/SED Co., Ltd. COMMENTS TSUKUB32(T-Ts): Missed scan 179-0730 due to synchronization failure in playback. Wettzell(V-Wz): Missed scan 179-0730 due to synchronization failure in playback. PF=2.0 STATION CLOCKS fmout-gps final clock drift clock drift [usec] [usec] [e-12sec] Ts 2.009 2.009 0.5571E-12 Wz -1.749 -1.879 -1.9006E-12 PROCESS SUMMARY BY BASELINE/FREQUENCY Base 0 1 2 3 4 5 6 7 8 9 D G N - Tot TV X 0 0 0 0 0 0 0 1 0 18 0 0 1 0 20 TV S 0 0 0 0 0 0 1 0 2 16 0 0 1 0 20 Column Totals, numbers then percentages 0 0 0 0 0 0 1 1 2 34 0 0 2 0 40 % .0 .0 .0 .0 .0 .0 2.5 --> --> 92.5 .0 .0 5.0 .0100.0 QC = 0 : Fringes not detected. = 1-9 : Fringes detected. The higher number, the better quality. = D : No data in one or more frequency channels. = G : Fringe amp in a freq ch is <.5 times coherent amp only if snr>20. = N : No valid correlator data. = - : Not scanned Base Line: TV Total Obs: 20 Error : 1 % : 5.0 (ERROR: Q-code of either band is less than 4 or letter code, or not scanned) SNR histogram Distribution of X-band SNRs, for each baseline SNR: 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 >> TV: 0 0 0 0 2 1 1 0 1 1 1 0 2 4 2 1 0 3 Total 0 0 0 0 2 1 1 0 1 1 1 0 2 4 2 1 0 3 Total number of obs: 19 Average SNR: 59.5 Distribution of S-band SNRs, for each baseline SNR: 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 >> TV: 0 0 0 2 0 2 0 1 2 1 3 3 0 1 0 0 0 4 Total 0 0 0 2 0 2 0 1 2 1 3 3 0 1 0 0 0 4 Total number of obs: 19 Average SNR: 60.0