WACO Correlator Report for R4004 (exp# 4004) Obs: 24,25 Jan. 2002 doy 024/025 Correlated: 07 Feb. 2002 to 11 Feb. 2002 Exported: done 93% Qcodes 5-9 3% Qcode 0 4% Qcodes BDEFG Station notes: Kokee (K): OK manual p-cal. Algonquin (G): OK Intermittant S-band interference in last channel Gilcreek (A): missed 025-1030 -> 1100 X-axis shutdown Ny Alesund (O): Receiver warm missed 024-1844 Az2 motor fault Wettzell (V): missed 025-0839 Az limit Hobart (H): Dropped channels: "c" (2257.99) track 29 out "e" (2377.99) track 30 out "h" (8222.99) track 4 out, 5 partially out "j" (8562.99) track 6 out S-band delay rate residuals show ionospheric disturbance. 54 scans (19%) reprocessed. 56 Hours processing. $ Note: This experiment was prepassed and run during the IVS General Meeting, in the absence of the regular staff. The clock offsets can lead to residual SBDs of ~1.0 usec. Clocks: Station fmout-gps Used rate Kk: 0.05 0.10 Ap: -0.80 2.00 Ny: -14.40 -14.07 Gc: -6.75 -5.56 Probably should be -6.56 Wz: 05.90 -4.67 -1.0e-12 Probably should be -5.67 Ho: 18.35 18.34 Qcodes 0 1 2 3 4 5 6 7 8 9 A B C D E F G H N - Tot ----------------------------------------------------------------------------- AK:X 0 0 0 0 0 0 3 2 11 148 0 0 0 0 0 0 0 0 0 4 168 AK:S 1 0 0 0 0 2 3 11 16 125 0 0 0 0 0 0 6 0 0 4 168 AH:X 3 0 0 0 0 0 0 2 18 44 0 0 0 0 0 0 0 0 0 0 67 AH:S 6 0 0 0 0 0 0 3 19 34 0 0 0 0 0 0 5 0 0 0 67 AO:X 2 0 0 0 0 0 2 3 14 150 0 0 0 1 0 0 0 0 0 7 179 AO:S 5 0 0 0 0 3 3 9 17 134 0 0 0 1 0 0 0 0 0 7 179 AG:X 1 0 0 0 0 0 3 2 15 147 0 0 0 0 0 0 0 0 0 4 172 AG:S 1 0 0 0 0 6 3 10 32 93 0 0 0 0 0 0 23 0 0 4 172 AV:X 1 0 0 0 0 1 0 4 24 113 0 2 0 0 0 0 1 0 0 5 151 AV:S 5 0 0 0 0 1 2 5 16 115 0 2 0 0 0 0 0 0 0 5 151 KH:X 0 0 0 0 0 1 1 4 48 111 0 0 0 0 0 0 0 0 2 1 168 KH:S 4 0 0 0 0 0 0 5 63 74 0 0 0 0 0 0 19 0 2 1 168 KO:X 2 0 0 0 0 0 0 1 9 81 0 0 0 1 0 0 0 0 0 0 94 KO:S 8 0 0 0 0 0 1 5 7 72 0 0 0 1 0 0 0 0 0 0 94 KG:X 2 0 0 0 0 0 0 0 5 121 0 0 0 0 0 0 1 0 1 0 130 KG:S 3 0 0 0 0 0 0 4 21 85 0 0 0 3 0 0 13 0 1 0 130 KV:X 0 0 0 0 0 0 0 1 8 39 0 0 0 0 0 0 0 0 1 0 49 KV:S 2 0 0 0 0 1 0 0 3 41 0 0 0 0 0 0 1 0 1 0 49 HO:X 4 0 0 0 0 0 0 0 1 21 0 0 0 0 0 0 0 0 1 0 27 HO:S 11 0 0 0 0 0 0 0 1 12 0 0 0 0 0 0 2 0 1 0 27 HG:X 0 0 0 0 0 0 0 1 8 9 0 0 0 0 0 0 0 0 0 0 18 HG:S 1 0 0 0 0 0 1 0 4 7 0 0 0 0 0 0 5 0 0 0 18 HV:X 7 0 0 0 0 0 0 3 4 14 0 0 0 0 0 0 0 0 0 0 28 HV:S 9 0 0 0 0 0 0 0 8 11 0 0 0 0 0 0 0 0 0 0 28 OG:X 1 0 0 0 0 1 2 5 16 112 0 0 0 0 0 0 1 0 0 0 138 OG:S 2 0 0 0 0 2 4 19 24 71 0 0 0 0 0 0 16 0 0 0 138 OV:X 2 0 0 0 0 0 0 3 30 222 0 0 0 2 0 0 0 0 0 1 260 OV:S 7 0 0 0 0 2 6 9 26 206 0 0 0 1 1 0 0 0 1 1 260 GV:X 1 0 0 0 0 0 1 0 14 116 0 0 0 0 0 0 2 0 0 0 134 GV:S 1 0 0 0 0 0 0 1 15 100 0 0 0 0 0 0 17 0 0 0 134 ----------------------------------------------------------------------------- Totals 92 0 0 0 0 20 35 112 497 2628 0 4 0 10 1 0 112 0 11 44 3566 3% >--->--->92% 3% Legend: QC = 0 Fringes not detected. = 1-9 Fringes detected, no error condition. Higher number = better quality. = B Interpolation error in fourfit. = D No data in one or more frequency channels. = E Maximum fringe amplitude at edge of SBD, MBD, or rate window. = F "Fork" problem in processing. = G Fringe amp in a channel is <.5 times mean amp (only if SNR>20). = H Low Phase cal amplitude in one or more channels = N No valid correlator data. Tot Total number of scans in schedule. Minus Scans in original schedule file for which correlation was not attempted, usually because of known station problems. MEAN RATIOS = Observed SNR / Predicted SNR for exp no. 4004 ...by baseline, over all sources: bl X n S n GA 1.24 167 1.14 167 GH 0.69 18 0.71 17 GK 1.18 126 1.11 126 GO 0.70 137 0.79 136 GV 1.31 132 1.35 133 AH 0.85 64 0.76 60 AK 1.28 164 1.17 163 AO 0.63 169 0.72 166 AV 1.23 143 1.24 139 HK 1.03 165 0.89 160 HO 0.45 22 0.47 15 HV 0.59 21 0.76 18 KO 0.66 90 0.70 84 KV 1.14 48 1.07 46 OV 0.71 255 0.89 247 Kerry