Starting generation of Calibration File FS version = 0009.0005.0001 time_zero = 31251600 Found #23 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #18 errors of type = ERROR un 12 Cannot allocate memory Found #17 errors of type = ERROR ib -300 GPIB(edvr) unix error see message above W1 Found #16 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #7 errors of type = ERROR qk -211 Tsys value for device ia overflowed or were less than zero. Found #7 errors of type = ERROR an -102 Pointing computer command angles are incorrect. Found #3 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 35K. Found #2 errors of type = ERROR qk -211 Tsys value for device ic overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device eu overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device au overflowed or were less than zero. Found #2 errors of type = ERROR mc -5 Interface fm failed to handshake on monitor. Found #2 errors of type = ERROR qk -211 Tsys value for device du overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device ib overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 3u overflowed or were less than zero. Found #1 errors of type = ERROR ib -300 GPIB(edvr) unix error see message above RE Found #1 errors of type = ERROR qk -211 Tsys value for device cu overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 4u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 5u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 1u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 2u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 6u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 7u overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 29 parity errors exceed threshold. Found #1 errors of type = ERROR ch -233 r1 tape drive should be moving and it isn't Found #1 errors of type = ERROR qk -211 Tsys value for device 8u overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device 9u overflowed or were less than zero. Found these BBCs: bbc02 bbc06 bbc11 NBBC: 3 Found these RX parameters: 00(front) 02(lo) 03(dcal) RX1 min= 24.11 max= 2001.361.17:32:34.21 RX2 min= 47.55 max= 47.68 RX3 min= 47.80 max= 48.29 Plotting 3 Tsys channels: 02 06 11 Tsysa values are: 1 2 3 etc Tsysb values are: 9 10 11 etc Tsysc values are: etc Tsysd values are: etc NTSYS: 3 in match_chan ft1= na452gc.log.tsy1.ntup nt1= 8 st1= 2u tt= 1 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max 71.8 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305 in match_chan ft1= na452gc.log.tsy1.ntup nt1= 12 st1= 6u tt= 1 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max 71.8 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 305 in match_chan ft1= na452gc.log.tsy2.ntup nt1= 9 st1= 11u tt= 2 set scale tsys1 [2] min max -5 305 set scale tsys2 [2] min max 71.8 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 66.8 ymax 305