Starting generation of Calibration File FS version = 0009.0004.0014 time_zero = 29264400 Rack type is MK3/4 Found #274 errors of type = ERROR ch -349 The Receiver 70K stage is hotter than 68K. Found #205 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #205 errors of type = ERROR qk -211 Tsys value for device v1 overflowed or were less than zero. Found #205 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #71 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #30 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #24 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #13 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #8 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #3 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #3 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #3 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #3 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #2 errors of type = ERROR qd -301 Synch block CRC checksum test FAILED. Found #2 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v7 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v2 overflowed or were less than zero. Found #1 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #1 errors of type = ERROR qk -211 Tsys value for device v3 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #1 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #1 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #1 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #1 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #1 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #1 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 44.13 max= 2001.338.17:46:50.02 RX2 min= 35.71 max= 36.93 RX3 min= 0.130 max= 0.134 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= na449ft.log.tsy1.ntup nt1= 8 st1= v2 tt= 1 set scale tsys1 [2] min max -5 223.2 set scale tsys2 [2] min max 124.9 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 241.8 in match_chan ft1= na449ft.log.tsy1.ntup nt1= 12 st1= v6 tt= 1 set scale tsys1 [2] min max -5 223.2 set scale tsys2 [2] min max 124.9 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 52.5 ymax 305 in match_chan ft1= na449ft.log.tsy2.ntup nt1= 9 st1= v11 tt= 2 set scale tsys1 [2] min max -5 223.2 set scale tsys2 [2] min max 124.9 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 119.9 ymax 305