Starting generation of Calibration File FS version = 0009.0004.0014 time_zero = 25635600 Rack type is MK3/4 Found #221 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #221 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #221 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #194 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #46 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #33 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #19 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #14 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #13 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #12 errors of type = ERROR ch -309 v5 alarm is on Found #12 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #12 errors of type = ERROR ch -307 v5 unlock indicator is on Found #9 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #7 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #5 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #5 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #4 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #4 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #4 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #3 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #2 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #2 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #2 errors of type = ERROR qd -301 Synch block CRC checksum test FAILED. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #1 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 35K. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #1 errors of type = ERROR ch -4 Device v5 timed-out on response from MATCN Found #1 errors of type = ERROR qk -211 Tsys value for device vd overflowed or were less than zero. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #1 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #1 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #1 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 43.89 max= 2001.296.17:40:00.36 RX2 min= 35.83 max= 37.05 RX3 min= 0.131 max= 0.135 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= na443ft.log.tsy1.ntup nt1= 8 st1= v2 tt= 1 set scale tsys1 [2] min max 56.8 108.6 set scale tsys2 [2] min max 41.2 169.9 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 58.6 ymax 126 in match_chan ft1= na443ft.log.tsy1.ntup nt1= 12 st1= v6 tt= 1 set scale tsys1 [2] min max 56.8 108.6 set scale tsys2 [2] min max 41.2 169.9 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 48.3 ymax 102.1 in match_chan ft1= na443ft.log.tsy2.ntup nt1= 9 st1= v11 tt= 2 set scale tsys1 [2] min max 56.8 108.6 set scale tsys2 [2] min max 41.2 169.9 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 36.2 ymax 174.9