Starting generation of Calibration File FS version = 0009.0004.0014 time_zero = 15354000 Rack type is MK3/4 Found #218 errors of type = ERROR ch -371 IF3 alarm is on Found #195 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #53 errors of type = ERROR qk -211 Tsys value for device v4 overflowed or were less than zero. Found #47 errors of type = ERROR qk -211 Tsys value for device va overflowed or were less than zero. Found #44 errors of type = ERROR ch -369 IF3 lo is unlocked. Found #25 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #22 errors of type = ERROR ib -4 GPIB Device time-out on response ca Found #15 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #15 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #12 errors of type = ERROR ma -4 Device i3 timed-out on response. Found #11 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #11 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #10 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #10 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #9 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #8 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #8 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #7 errors of type = ERROR ch -304 v5 TPI selection does not check with requested setting Found #7 errors of type = ERROR ch -330 Formatter alarm is on Found #7 errors of type = ERROR qy -1 Error in response from counter. Found #7 errors of type = ERROR ch -303 v5 bandwidth does not check with requested value Found #7 errors of type = ERROR ch -306 v5 LSB attenuator does not check with requested setting Found #6 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #6 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #6 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #6 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #4 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #3 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #3 errors of type = ERROR qk -211 Tsys value for device i1 overflowed or were less than zero. Found #2 errors of type = ERROR ch -4 Device i3 timed-out on response from MATCN Found #2 errors of type = ERROR qk -211 Tsys value for device v5 overflowed or were less than zero. Found #2 errors of type = ERROR ch -360 IF3 module shows the majority of possible error conditions Found #2 errors of type = ERROR sp -4 Unrecognized name (not a function or procedure). Found #2 errors of type = ERROR qk -211 Tsys value for device v8 overflowed or were less than zero. Found #2 errors of type = ERROR qk -211 Tsys value for device v6 overflowed or were less than zero. Found #1 errors of type = ERROR ch -339 Bypass mode does not check with requested setting Found #1 errors of type = ERROR ch -370 Total power integrator overflow on IF3 Found #1 errors of type = ERROR ch -316 Total power integrator overflow on IF1 Found #1 errors of type = ERROR ma -4 Device v2 timed-out on response. Found #1 errors of type = ERROR ch -309 vb alarm is on Found #1 errors of type = ERROR ma -4 Device v3 timed-out on response. Found #1 errors of type = ERROR ma -4 Device v4 timed-out on response. Found #1 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #1 errors of type = ERROR qg -304 Track 19 sync errors exceed threshold. Found #1 errors of type = ERROR ch -363 IF3 mixer state does not check with request. Found #1 errors of type = ERROR qk -211 Tsys value for device v9 overflowed or were less than zero. Found #1 errors of type = ERROR ch -338 Reproduce equalizer does not check with request Found #1 errors of type = ERROR ch -317 Total power integrator overflow on IF2 Found #1 errors of type = ERROR qk -211 Tsys value for device i3 overflowed or were less than zero. Found #1 errors of type = ERROR ch -309 v4 alarm is on Found #1 errors of type = ERROR q+ -201 if3 attenuation must be one of 0 ... 63 max or old. Found #1 errors of type = ERROR ch -309 v7 alarm is on Found #1 errors of type = ERROR ch -309 v8 alarm is on Found #1 errors of type = ERROR ch -362 IF3 attenuator does not check with requested value. Found #1 errors of type = ERROR ch -337 Reproduce bandwidth does not check with request Found #1 errors of type = ERROR ch -341 Reproduce track B does not check with request Found #1 errors of type = ERROR ch -340 Reproduce track A does not check with request Found these BBCs: vc02 vc06 vc11 NBBC: 3 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 43.65 max= 2001.177.17:40:17.65 RX2 min= 36.08 max= 37.30 RX3 min= 0.130 max= 0.135 Plotting 3 Tsys channels: 02 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 3 in match_chan ft1= na426ft.log.tsy1.ntup nt1= 8 st1= v2 tt= 1 set scale tsys1 [2] min max 55.8 142.4 set scale tsys2 [2] min max 136.3 245.7 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 54.8 ymax 159 in match_chan ft1= na426ft.log.tsy1.ntup nt1= 12 st1= v6 tt= 1 set scale tsys1 [2] min max 55.8 142.4 set scale tsys2 [2] min max 136.3 245.7 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin -5 ymax 127.3 in match_chan ft1= na426ft.log.tsy2.ntup nt1= 9 st1= v11 tt= 2 set scale tsys1 [2] min max 55.8 142.4 set scale tsys2 [2] min max 136.3 245.7 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 131.3 ymax 250.7