Starting generation of Calibration File FS version = 0009.0004.0014 time_zero = 738000 Rack type is MK3/4 Found #214 errors of type = ERROR qk -211 Tsys value for device ve overflowed or were less than zero. Found #52 errors of type = ERROR qg -303 Track 13 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 23 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 25 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 1 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 3 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 5 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 17 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 15 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 7 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 11 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 9 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 21 parity errors exceed threshold. Found #52 errors of type = ERROR qg -303 Track 19 parity errors exceed threshold. Found #39 errors of type = ERROR qg -304 Track 21 sync errors exceed threshold. Found #36 errors of type = ERROR qg -304 Track 19 sync errors exceed threshold. Found #26 errors of type = ERROR qg -303 Track 27 parity errors exceed threshold. Found #23 errors of type = ERROR qg -304 Track 25 sync errors exceed threshold. Found #22 errors of type = ERROR ch -336 Enabled tracks do not check with requested tracks Found #20 errors of type = ERROR qg -304 Track 15 sync errors exceed threshold. Found #17 errors of type = ERROR qg -304 Track 11 sync errors exceed threshold. Found #17 errors of type = ERROR qg -304 Track 17 sync errors exceed threshold. Found #13 errors of type = ERROR qg -304 Track 5 sync errors exceed threshold. Found #13 errors of type = ERROR qg -304 Track 23 sync errors exceed threshold. Found #12 errors of type = ERROR qg -304 Track 3 sync errors exceed threshold. Found #12 errors of type = ERROR qg -304 Track 13 sync errors exceed threshold. Found #11 errors of type = ERROR qg -305 AUX data differs from expected value on track 19. Found #8 errors of type = ERROR qg -305 AUX data differs from expected value on track 7. Found #8 errors of type = ERROR qg -304 Track 7 sync errors exceed threshold. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 5. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 23. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 25. Found #7 errors of type = ERROR qg -305 AUX data differs from expected value on track 15. Found #6 errors of type = ERROR qg -305 AUX data differs from expected value on track 21. Found #6 errors of type = ERROR ch -350 The Receiver 20K stage is hotter than 35K. Found #6 errors of type = ERROR qg -305 AUX data differs from expected value on track 13. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 11. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 27. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 3. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 17. Found #5 errors of type = ERROR qg -305 AUX data differs from expected value on track 9. Found #4 errors of type = ERROR qg -304 Track 27 sync errors exceed threshold. Found #4 errors of type = ERROR qo -301 WARNING: ONSOURCE status is SLEWING! Found #4 errors of type = ERROR ch -351 Tape head 1 is not in requested position. Found #4 errors of type = ERROR qg -304 Track 9 sync errors exceed threshold. Found #4 errors of type = ERROR an -103 Pointing computer tracking errors are too large. Found #3 errors of type = ERROR ch -352 Tape head 2 is not in requested position. Found #3 errors of type = ERROR qg -304 Track 1 sync errors exceed threshold. Found #2 errors of type = ERROR qk -211 Tsys value for device i2 overflowed or were less than zero. Found #2 errors of type = ERROR ch -201 hd communication trouble Found #2 errors of type = ERROR qg -305 AUX data differs from expected value on track 1. Found #1 errors of type = ERROR st -503 Az signal failure Found #1 errors of type = ERROR ch -345 Tape drive alarm is on Found these BBCs: vc06 vc11 NBBC: 2 Found these RX parameters: 02(LO) 03(DCAL) 0E(LO5MHZ) RX1 min= 40.47 max= 2001.008.13:51:02.00 RX2 min= 33.88 max= 34.61 RX3 min= 0.131 max= 0.135 Plotting 2 Tsys channels: 06 11 Tsys1 values are: 1 2 etc Tsys2 values are: 9 10 etc Tsys3 values are: etc NTSYS: 2 in match_chan ft1= is158ft.log.tsy1.ntup nt1= 12 st1= v6 tt= 1 set scale tsys1 [2] min max 49.9 97.5 set scale tsys2 [2] min max 305 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 42.2 ymax 96 in match_chan ft1= is158ft.log.tsy2.ntup nt1= 9 st1= v11 tt= 2 set scale tsys1 [2] min max 49.9 97.5 set scale tsys2 [2] min max 305 305 set scale tsys3 [2] min max set scale tsys4 [2] min max Tsys scale ymin 300 ymax 305