  Correlator Notes (B O N N Correlator)
  IRIS-S 153          No#1568 
  2000/227 = MON,AUG 14,2000  start
  2000/228 = TUE,AUG 15,2000  stop
  
  STATION COMMENTS
  Gc :  not observed : telescope hydro failure
  Ft :  normal
        missed scans because of FS crashes
        tape parity errors are worse
        lost of several scans
  Hh :  normal                                            
  Wz :  normal                                
        INT break for 2 hours           
  Wf :  normal

  CLOCK
  def Ft ; 2000y227d14h00m :  0.07 usec    0.0   
  def Gc ; 2000y227d14h00m : -6.40 usec    0.0  
  def Hh ; 2000y227d14h00m :-52.36 usec    0.0   
  def Wf ; 2000y227d14h00m :  6.45 usec    0.0  
  def Wz ; 2000y227d14h00m : -1.34 usec    0.0    
  def Tg ; 2000y227d14h00m :  0.0  usec    0.0   

  REFRINGE/CORRELATION   
  Reprocess: a huge number of scan (Ft problem)
  Refringe:      
  * Fortleza bad tracks (tape parrity errors are worse)
  * freq. 8862.99
  if station F and f_group X
  freqs g h i j k l m

  * freq. 2297.99  2322.99
  if station F and f_group S
  freqs a b c e                                             

  STATISTICS:
  more than 90% of good data (FQ 6-9)
 
  REMARKS
  * processed files archived on DAT in standard  
    UNIX tar format (DDS2) inl. logfiles etc.
  * up to now database version1 is available at     
    the analysis Center BKG LEIPZIG or on 
    anonymous ftp at mpifr-bonn.mpg.de 
    directory outgoing/mueskens/database 
  
                                   regards
                                   GeoVLBI-Group
                                   BonnCorr